Consider An Emergency Generator

Author : by Steven S. Ross
Should you supplement battery-based uninterruptible data center power supplies with an emergency generator? Vendors say the question has been coming up with increasing frequency as word spreads about summer rolling blackouts and brownouts and drops in service reliability. Two years ago, 50 million people in eight states from the Midwest to New York lost power for at least 24 hours in one giant blackout.

Amercan Power Conversion and other vendors note that specific localities can have much higher outage rates, either because of building-specific problems or bad weather (lightning strikes in the Southeast, for example, or tornadoes in the Midwest). In a rolling blackout, power to industrial facilities is often shut down first. New data center managers should check the utilities contract to see if the data center is subject to such utility disconnects.

A Growing Problem

“Deregulation of the power industry has had a real effect on people’s needs to support their systems during shutdowns or to ride through a shutdown,” says Bill Hunt, product line manager for the power generation systems group at APC. Despite that, he says, customers typically admit that they’ve considered a backup generator but rejected the idea because of the design work required.

“A UPS provides clean power, guarding against surges and drops,” says Dan McHugh, project manager at PTS Data Center Solutions. “In order to provide longer-term power, you’d need racks and racks of batteries. A generator allows you to be out two to three days, so you’re not losing money.” http://www.ptsdcs.com">PTS is a consulting firm that does design work, construction, or construction management.

Says Hunt, “Our small and medium business customers started to come to us looking for longer runtimes. It used to be seven to 10 minutes, and now they were asking for two hours or more.” A well-designed emergency generator can run for days.

A data center with seven to 12 racks full of equipment needs 20KW to 40KW to stay up. The cost, installed with proper electronics for testing as well as for emergencies, with noise and air pollution controls, is typically $35,000 to $40,000, vendors say?after warning that installation costs can vary enormously.

Vendors say that units up to 20KW, on a concrete ground-level pad, are standard enough in many circumstances to be “ordered on the phone,” in Hunt’s words. But anything larger will require some specialized expertise and more careful configuration. Local electrical and HVAC contractors can point data center personnel in the right direction.

It is little wonder that data center management worries about the cost. But over time, the price doesn’t seem as high. “That’s about the same as an extra 45 minutes to an hour’s worth of batteries,” says Hunt, “amortized over about 10 years.” As the kilowatt requirements rise, the generator option gets cheaper by comparison. But site problems, especially lack of space outside the building to pour a concrete pad for the generator and noise-attenuating enclosure, can inflate the cost quickly.

Michael Dauffenbach, industrial sales region manager for Katolight, says the generator itself might be only a third or half the total cost. “A 15KW gas [typically propane] unit’s list price is about $10,000,” he says, “and diesel is about the same.”

As capacity increases, diesel prices rise more slowly than gas. At 250KW, diesels cost about $45,000 and gas $90,000, again, for the generator alone. APC doesn’t see propane or natural gas as practical above 150KW. About a quarter of the units APC sells run on gas, with the rest on diesel fuel.

Makers of fuel cells, which would replace generators, are just beginning to test the marketplace, as well. Fuel cell installations promise to be simpler, as there are no noise or pollution issues and units are fairly compact. But costs are unclear.

Data center personnel also worry about maintaining and testing. “Very few companies want to schedule a test once a month or once a week. I don’t think they exist. I never heard of one,” says McHugh. For the average small to medium-sized enterprise, weekly tests are probably unnecessary. However, larger companies may need to test more often.

“In a hospital or nursing home, the JCHA [Joint Commission on Hospital Accreditation] recommends testing emergency generators once a week. They have to test under load and keep maintenance logs. How important is your data?” says Dauffenbach.

The best test is to use “building mode.” You simply simulate a power outage by cutting off power from outside. “Data centers don’t like to do that,” says Dauffenbach.

A compromise: Use a transition transfer switch. To test, or if you think an outage is coming, turn the generator on first, synchronize the generator’s output with the utility’s power, and then open the switch to cut off the utility supply.

A more common approach is simply to turn on the generator once a week or once a month, while the utility continues to provide power to the data center. Testing the generator that way, without connecting to an external load (the equipment in the data center itself), puts extra strain on it. Generator vendors recommend simulating the load by installing a “dummy” load bank. The power can be dissipated with resistive wire (“Think of it as a giant toaster,” says Dauffenbach) or with inductive or capacitative loads. A 10KW load bank can cost $4,000 or more, depending on its type and its adjustability.

APC offers an annual service itself or through business partners worldwide. Under the service plan, you can contract to have a test under load done periodically. The APC technicians arrive with their own load bank. “We also recommend testing under real load. Maybe quarterly, on a Sunday, shut down all noncritical processing tasks, check the UPS batteries, and pull the plug,” says Hunt.

The emergency generator business is dominated by local firms, working with local design consultants and electrical contractors. Among those suppliers who distribute nationally in addition to APC are Detroit Diesel, John Deere, and Caterpiller. You’ll be referred to a dealer-distributor such as Bowers Power, Covington Detroit Diesel-Allison, and GoPower.com.

Figuring The Size

Estimating the generator size you might need involves more than adding up the data center’s computer demand. Should you include power for air conditioning? “If you plan being on the generator for no more than 20 or 30 minutes, you may not need air conditioning,” says McHugh. “But after 30 minutes, our preference is that at least a portion is put onto the generator. A handful of lights is enough.”

If you include air conditioning, you will have to add extra generating capacity to allow for transient loads. Air conditioners, fans, and similar equipment start under load and draw far more than their rated power needs for a few seconds.

How to sell it to the boss? “It comes down to dollars for everybody,” says McHugh. “What does this cost your company if you have a two-hour outage and you have a half-hour battery? Is this cost in the hundreds of thousands? Millions?”


About the Author

None

Related articles


  1. Abandoned Academic Research Often Lost
  2. World Wildlife Fund: Where Have All those Animals Gone; Long Time Coming?
  3. Chinese Academy of Sciences Keeping Up with DARPA
  4. Monsters of Traditional Lore: Dinosaurs by Other Names?
  5. How to Stop the Sixth Extinction
  6. NASA Astrobiology Cuts Are Unfortunate
  7. Mars as a Relay Base Station for Exploring the Solar System
  8. The Snuffed Out Candles - A Science Inquiry Demonstration of Density
  9. Genetic Memory - True or False?
  10. Battery Voltage
  11. Who Was Nikola Tesla?
  12. Rising Raisins and Pop Bottle Fountains - A Science Inquiry Experience - Part 1
  13. Wild Animal Intelligence is Often Hiding From View
  14. Animals in Captivity May Not Take Learned Skills Back to the Wild
  15. Packaging - Alufoil And Microwaves
  16. Humans and Chimpanzees are Cousins
  17. Humans are Unique to Animals; Are We Sure?
  18. Humans Are Not Animals And Animals Are Not Human
  19. Categories of Human and Animal Life
  20. What Makes Humans So Unique To Other Life Forms On Earth?
  21. Absolute Roots and Focus in Scientific Experimentation
  22. The Theory of God
  23. Research Ethics, Experimentation, Peer Review, and Focus
  24. Could Our Solar System Be Slowing Down?
  25. Improving the quality of Research through Personalization, Autonomy, Reflection and Completion

 

More Articles Advertising Copywriting E-Mail Marketing Internet Marketing Link Popularity Marketing Marketing Strategy Newsletters Online Business PPC Advertising Public Relations Sales Scams S E Optimization S E Positioning S E Tactics Search Engines Self Improvement Site Security Spam Web Development Web Hosting Webmasters Writing

Featured Articles :
Auto and Trucks | Business and Finance | Computers and Internet | Education | Food & Drink | Home Improvement | Kids and Teens | Legal | Marketing | Online Business | Pets & Animals | Parenting | Recreation and Sports | Self Improvement and Motivation | Site Promotion | Travel and Leisure | Web Design and Development | Women

ArticlesClick.com || More Articles || More Authors || Tips || E-Books || Resources

2007 Articles Click  / Articles.articlesclick.com Email : info(AT)articlesclick.com  Powered by Destiny Infotek Limited

Partner Links: Linux Web Hosting | Web Hosting | SMS Plug-in | Readymade Logo Design | Web Templates Affiliate | SEO Top Ranking | Ebooks  Webmaster | Register Domain Name | Hindustanlink | MT & BPO Forum | Medical Transcription | BPO Services India | Mobile Phone Forum | Send Gifts to India | RSS Feed Guide | Search E-books | Downloadable ebooks | BPO | SEO Services | Mehendi World | Destiny | Web-link | Beauty Care Forums | Web Hosting India | Logo Design | Home Based Business | Google SiteMap Maker | India Tourist Places | Medical Transcription | Mehendi Blog | Teachers Forum | BSE Sensex | Digital Signature Certificate | Discuss | Manoj Jain's Blog | Jigg | Chartered Accountant | Hosting Directory | Free Blog | Honeymoon Tips | Wallpapers | BPO Portal

ArticlesClick.com makes no representations regarding either the products or external links.
The products and external links referenced in this site are provided by parties other than ArticlesClick.com